Electrical Differential Pressure Indicator - Code EE
Electrical Differential Pressure Indicator Code EE
The Electrical Differential Pressure Indicator - Code EE is a filtration monitoring accessory supplied by Canglobal (M) Sdn Bhd for industrial filter systems. Developed within the Norman Filter Company accessory range, it provides an electrical switching signal when differential pressure reaches the specified setting, helping operators monitor filter conditions through connected control equipment.
The indicator is particularly useful where direct visual inspections are difficult or centralised equipment monitoring is preferred. Featuring a normally open reed switch and automatic reset function, Code EE supports practical filter condition monitoring when correctly matched to the compatible filter assembly and electrical control system.
Product Features & Monitoring Benefits
Electrical Differential Pressure Monitoring for Industrial Filters
The Code EE electrical indicator lets you monitor filtration equipment without relying solely on routine visual inspection. When connected to an appropriate control system, the indicator can provide a switching signal as differential pressure increases, supporting timely maintenance awareness and filter condition assessment.
- Normally open reed switch design for differential pressure indication.
- Standard Code EE switching setting of 40 PSID.
- Alternative published settings include EE20 at 20 PSID and EE75 at 75 PSID.
- Designed for mounting on top of the compatible filter unit.
- Available in anodised, corrosion-resistant aluminium or 303 stainless steel.
- Switch contacts close as differential pressure reaches the selected setting.
- Automatic reset function when differential pressure decreases.
- Suitable for integration with appropriately rated monitoring and signal equipment.
Product Specifications
The following specifications are provided in the Norman Filter Company accessories catalogue. Confirm electrical and mechanical compatibility against the specific filter assembly and monitoring installation.
Monitoring Applications
- Remote Filter Monitoring: Suitable for applications where routine visual inspection is difficult due to equipment location.
- Centralised Control: Electrical switching signals can be used with compatible central monitoring systems.
- Filter Condition Indication: Detects when differential pressure reaches the configured switching threshold.
- Industrial Maintenance: Supports maintenance awareness by indicating changes in filter pressure differential.
- Filtration Equipment: Listed for compatible Norman 4500, 4900 and U-115 Tee Type filter configurations.
Selection Requirements
- Pressure Setting: Identify whether EE, EE20 or EE75 is required.
- Filter Compatibility: Confirm the exact model, filter head and accessory mounting arrangement.
- Electrical Rating: Check the connected load against the 10 W DC, 10 VA AC and 0.5 A ratings.
- Control Interface: Confirm the switching signal and monitoring equipment requirements.
- Material Selection: Consider anodised aluminium or 303 stainless steel as appropriate.
- Replacement Reference: Retain the full filter assembly identification and indicator code when ordering.
Electrical Ratings & Installation Considerations
The Norman Filter catalogue identifies Code EE as a normally open electrical differential pressure indicator with a standard 40 PSID setting. EE20 and EE75 represent 20 PSID and 75 PSID alternatives respectively. The published electrical ratings are 10 W DC resistive, 10 VA AC resistive and 0.5 A switch current. A relay is required for heavier electrical loads. The indicator is not automatically certified for hazardous-area use; any explosion-protected configuration requires separate verification. Final installation, connection and compatibility should be confirmed by qualified personnel using the applicable manufacturer documentation.
Frequently Asked Questions
Understanding Code EE Differential Pressure Monitoring
What is Code EE used for?
Code EE is an electrical differential pressure indicator used with compatible filtration equipment. It provides an electrical switching signal when the differential pressure reaches the selected set point, allowing filter conditions to be monitored through connected equipment.
What is the standard pressure setting?
The standard Code EE set point is 40 PSID. The manufacturer catalogue also identifies EE20 at 20 PSID and EE75 at 75 PSID. The appropriate setting depends on the filter and maintenance requirements.
Can the indicator support remote monitoring?
Yes. The indicator can be wired into an appropriate central control panel to provide an electrical switching signal. Actual alarm, display or monitoring functions depend on the connected control system.
Does Code EE reset automatically?
Yes. According to the Norman Filter catalogue, the normally open reed switch closes as differential pressure increases and automatically resets when differential pressure decreases.
Which filtration systems support this accessory?
The Norman Filter accessories catalogue lists electrical indicators for the 4500, 4900 and U-115 Tee Type filter families. Compatibility must still be checked for the specific model and configuration.
Who supplies the Electrical Differential Pressure Indicator?
Canglobal (M) Sdn Bhd supplies the Electrical Differential Pressure Indicator - Code EE as part of its industrial filtration product offering. The company has operated since 2001, supporting industrial filtration and equipment reliability requirements.
Looking for an Electrical Differential Pressure Indicator?
Contact Canglobal (M) Sdn Bhd to enquire about the Electrical Differential Pressure Indicator - Code EE, available pressure settings, electrical ratings and compatible filtration equipment. Share your existing filter model, required PSID set point and control system specifications so our team can assist with product identification and purchasing enquiries.
Inquiry - Electrical Differential Pressure Indicator - Code EE